PSU Power Supply
-
Mains Input Voltage
120VAC (90-264VAC, 47-63Hz)
Mains Input Operating Current
20VAC 1.5A (Full Load)
DC Output (Combined)
12.64VDC 4.0A Max (V1 Out + V2 Out Total)
DC Output (Single)
12.2VDC 3A Max
Battery Charging
500mA (Typical) *Additional to the 4A Combined DC Output
Batetry Low
11.75VDC
Battery Restore
12.5VDC
Controller Power Supply
-
Operating Voltage
11-14V DC
Operating Current
120mA (typical)
DC Output (Auxiliary)
10.45-13.85VDC 0.7A (typical) electronic shutdown at 1.1A
Bell DC Output (Continuous)
10.4-13.45VDC 8 Ohm 30W Siren or 1.1A (Typical) Electronic Shutdown at 1.6A
Bell DC Output (Inrush)
1500mA
Total Combined Current*
3.4A (max)
Electronic Disconnection
9.0VDC
Keypad Power Supply
-
Operating Voltage
11-14V DC
Operating Current
60mA (95mA Max)
tSec Reader Power Supply
-
Operating Voltage
12VDC (9.5 to 14VDC)
Operating Current
tSec Standard Reader: 254mA (Peak, Reading); tSec Mini Reader: 203mA (Peak, Reading)
Controller Communication
-
Ethernet
10/100Mbps Ethernet communication link
RS-485
3 RS-485 communication interface ports, 1 for module communication and 2 for reader communication
Modem
2400bps modem communication
Controller Reader Ports
-
Readers
2 reader ports that can be independently configured for either Wiegand (up to 1024 bits configurable) or RS-485, allowing connection of up to 4 readers providing entry/exit control for two doors // RS-485 reader port connections support configuration for OSDP protocol
Inputs
-
Controller (System) Inputs
8 high security monitored inputs
PSU Inputs
Dedicated Hardware Tamper Input, 8 Trouble Inputs (internal)
Keypad Inputs
2 standard or 4 using Input Duplex mode
Outputs
-
Controller Outputs
4 50mA (max) open collector outputs for reader LED and beeper or general functions; 2 Form C relays - 7A N.O/N.C. at 30 VAC/DC resistive/inductive
PSU Outputs
2 Solid-State Relay Outputs, 50mA 12V Max each
Keypad Outputs
1 open collector (50mA Max) output. Programmable for all output functions; 3 system status LEDs; 1 system beeper
Keypad User Interface
-
User Interface Display
Energy smart backlit LCD 16x2 alphanumeric display with enhanced viewing angle
User Interface Keypad
Combined 23 key capacitive touch keypad with 3 system status LEDs
tSec Reader Communications
-
Card Read Range
DESFire EV1 ISO 15mm (0.6")
Tag Read Range
DESFire EV1 6mm (0.23")
Wiegand Interface
Multiple format 26 or 34 Bit data 0 and data 1, card defined
Frequency
13.56 MHz ISO/IEC 14443 Type A
Multi Conductor Cable
Wiegand: 22Awg alpha 5196, 5198, 18Awg alpha 5386, 5388. Max Distance 150m (492ft) Module comms/RS485: Belden 9842 or equivalent. Max distance 900m (3000ft)
OSDP Communication
OSDP standard 2.1.5 with Secure Channel Protocol
Bluetooth® Wireless Technology
-
Bluetooth® Read Range
Proximity mode: up to 0.5m (1.6ft) Configurable Action unlock (shake): up to 5m (16.4ft) Configurable
Bluetooth® Electronic Credential Transmission Technology
NRF8001 Bluetooth® version 4.0 compliant; Proprietary data exchange protocol. AES128 Encrypted; Reader App Version: 1.04.175 and above; Credentials can be distinguished by unique site code and card number
Bluetooth® Wireless Device
Protege Mobile 1.0.x
NFC
-
NFC Read Range
Up to 60mm
NFC (Near-field communication) electronic credential transmission technology
Android 4.4 or above, with phones which support ISO7816-4; Proprietary Secured DESFire credential; Credential is AES-256 (NIST certified AES algorithm); Reader App Version: 1.04.175 and above; Credentials can be distinguished by unique site code and card number
NFC Wireless Device
Protege Mobile 1.0.x
Dimensions
-
Dimensions (L x W x H)
330 x 180 x 300mm (13 x 7.1 x 11.8")
Net Weight
4.4kg (9.7lb)
Gross Weight
5.9kg (13lb)
Operating Conditions
-
Operating Temperature
-10° to 55°C (14° to 131°F)
Storage Temperature
-10˚ to 85˚C (14˚ to 185˚F)
Humidity
0%-93% non-condensing, indoor use only (relative humidity)