The Protege Half DIN Rail 2 Door Reader Expander is a compact, versatile solution designed to enhance access control and building automation systems. This two-tier half DIN rail device supports up to four reader inputs and two locking device outputs, making it ideal for dual entry and exit door configurations. With eight inputs for extended monitoring and six open collector outputs for managing controllable devices, this expander provides flexible security, alarm monitoring, and automation capabilities.

Key features include two reader ports, independently configurable for Wiegand or RS-485 operation, and support for OSDP-configurable RS-485. It also offers a fused and monitored reader power supply, ensuring reliable performance. Designed for easy installation with industry-standard DIN rail mounting, the expander supports intelligent tamper operation and includes offline functions like No Users, All Users, and First 10 Users plus 150 Card Cache. With over 40 predefined reading formats and the ability to control up to three outputs per reader port, the Protege Half DIN Rail 2 Door Reader Expander is a robust solution for comprehensive access control management.

Form Factor DIN Rail
Door Expander Door Expander
DC Input Voltage 11-14VDC
CC Output Voltage (DC IN Pass-Through) 10.83-14.0VDC 0.7A (typical) electronic shutdown at 1.1A
(DC IN Pass Through) Reader 1&2 10.45-13.85VDC pass through share 0.7A (typical) electronic shutdown at 1.1A
Operating Current 80mA (Normal Standby)
Total Combined Current* 1.6A (max)
Low Voltage Cutout 8.7VDC
Low Voltage Restore 10.5VDC
RS-485 Module network
Offline Access Modes AllUsers, First 10Users plus 150Card Cache,No Users
ReaderConfigurations 2 reader ports that can be independently configured for either Wiegand (up to 1024 bits configurable) or RS-485, allowing connection of up to 4 readers providing entry/exit control for two doors ** // RS-485 reader port connections support configuration for OSDP protocol
Lock Outputs 2 Form C Relay Outputs - 7A N.O/N.C. at 30VAC/DC resistive/inductive
PGM Outputs 6 (50mA Max) Open Collector
Zone Inputs 8 high security monitored inputs (10ms to 1hr input speed programmable)
Trouble Inputs 16
Dimensions (L x W x H) 78 x 90x 60mm (3.07 x 3.54 x 2.36")
Net Weight 207g (7.3oz)
Gross Weight 270g (9.5oz)
Operating Temperature UL/ULC 0° to 49°C (32° to 120°F) : EU EN -10° to 55°C (14° to 131°F)
Storage Temperature -10°- 85°C (14° - 185°F)
Humidity 0%-93% non condensing, indoor use only (relative humidity)
Mean Time Between Failures (MTBF) 622,997 hours (calculated using RFD 2000 (UTE C 80-810) Standard)
* The Total Combined Current refers to the current that will be drawn from the external power supply to supply the expander and any devices connected to its outputs. The Auxiliary outputs are directly connected via thermal resettable fuses to the N+ N- input terminals, and the maximum current is governed by the trip level of these fuses.